  agilent n4915a-005 serial bus switch data sheet version 1.1 6.5 gbit/s 2 to 1 switch for high speed differential signals low effect on signal integrity allows for usage in physical layer test setups fast switching time (6ns typical) manual and triggered operation supported by agilent n5990a test automation software no external power supply required ? ? ? ? ?
2 agilent n4915a-005 serial bus switch data sheet version 1.0 overview the n4915a-005 serial bus switch is designed for high speed serial bus applications, such as for example serial-ata and pci express. it can quickly switch between one source and two sink devices or one sink and two sources while having a minimal effect on signal integrity. serial bus interface the switch is designed for switching a differential signal as typically used in high speed serial bus applications. therefore the switch comes with two channels that switch simultaneously. figure 1 illustrates a typical setup with two trans- mitters that are switched between one receiver. analogously two receivers can be switched between one transmitting device. figure 1: typical switch setup with two transmitters for both channels the common connector (labeled ?c?) will be switched between connector ?1? and ?2?. the switch position display will indicate the current switch state by either illuminating a red (connector 1) or a green (connector 2) led. power supply the switch doesn?t require any power supply, it operates solely on usb power via its back side mini usb connector. it interfaces to any standard usb host, as provided by many agilent instruments or by any standard pc. it doesn?t require any host soft- ware or driver installation. the switch doesn?t have a dedicated power indica- tor. as soon as one of the switch position and one of the trigger mode leds are illuminated the switch is powered and in normal operation. parameter value note max. usable data rate 6.5 gbit/s signal inputs/outputs ac coupled 100 nf at each connector max. signal amplitude per channel 1v @ 70 khz to 12 ghz 2v @ 100 mhz to 12 ghz max. signal amplitude two channels differential 2v @ 70 khz to 12 ghz 4v @ 100 mhz to 12 ghz signal attenuation 1.5 db (15%) typical at 6 gbit/s transition times (20%-80%) 40 ps typical when used with j-bert n4903a switching time 6 ns typical total jitter (p-p) 20 ps typical 1) skew between channels 2 ps typical connectors sma, 3.5 mm female power supply usb 1) total jitter was measured with j-bert n4903a and 86100c dca-j with precision time-base using the following settings: ber 10 -12 , data rate 3 gbit/s, pattern 2 15 -1 prbs table 1: n4915a-005 electrical characteristics figure 2: n4915a-005 connector view
agilent n4915a-005 serial bus switch data sheet version 1.0 3 operation modes the switch is controlled by four buttons on the front panel. its current operation mode and switch position are illustrated by front panel leds. both trigger modes make use of the trigger input. the trigger mode buttons allow the user to switch between a level static trigger mode and an edge trig- ger mode. in edge trigger mode the manual pre-set buttons are also active. as an edge trigger toggles between the two switch positions the pre-set func- tion allows the switch to initialize at a desired state. for a manual only operation the edge/man trigger mode will be used and the trigger input will remain open. figure 3: n4915a-005 front view with status leds trigger input the trigger input is designed to be interoperable with agilent bit error ratio testers such as the j-bert n4903a as well as agilent pulse pattern generators such as the 81134a. for usage with j-bert?s trigger output choose the edge trigger mode. when connecting to the output of a pulse pattern generator the level static mode can be used. table 2: n4915a-005 trigger input electrical parameters parameter value trigger input max. levels 3v trigger threshold 10 mv max. trigger rate 10 mhz trigger input connector sma, 3.5 mm female usage in test automation and serial-ata receiver compliance test because of its external trigger modes the switch can be controlled by other test equipment. test equip- ment with integrated sequencing capabilities, such as the j-bert n4903a can control the switch posi- tion as part of a pattern sequence. furthermore, setups with multiple channels, such as the 81134a pulse pattern generator or the parbert 81250 systems can dedicate a data channel to control the switch. some test applications require the user to change cables between tools, for example in serial-ata receiver compliance testing, different tools are needed for turning on the test mode and for per- forming the actual test. without a serial bus switch this requires a change of cables as part of the test procedure. changing cables is certainly undesired in test au- tomation as it consumes additional time and labor. in order to avoid connectivity errors and preserve mechanically sensitive test ? xtures, setup changes should also be avoided. therefore in serial-ata the n5990a test automa- tion software has capabilities to remotely control two switch devices to avoid manual steps. besides test automation in serial-ata the switches also overcome the device disconnect issue: after the test mode is turned on on a serial-ata product, it doesn?t necessarily allow the user to manually change the connectors. being disconnected causes some devices to return to the out-of-band mode. such products can still be tested when using the serial bus switch. because of the fast switching time serial-ata products won?t detect a signal loss while being switched between test tools. ordering information 6.5 gbit/s 2 to 1 serial bus switch n4915a-005
remove all doubt our repair and calibration services will get your equipment back to you, performing like new, when promised. you will get full value out of your agilent equipment throughout its lifetime. your equipment will be serviced by agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. you will always have the utmost confidence in your measurements. agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite edu- cation and training, as well as design, system integration, and project management. for more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt for more information on agilent technologies products, applications or services, please contact your local agilent office. the complete list is available at: www.agilent.com/find/contactus phone or fax united states: korea: (tel) 800 829 4444 (tel) (080) 769 0800 (fax) 800 829 4433 (fax) (080)769 0900 canada: latin america: (tel) 877 894 4414 (tel) (305) 269 7500 (fax) 800 746 4866 china: taiwan: (tel) 800 810 0189 (tel) 0800 047 866 (fax) 800 820 2816 (fax) 0800 286 331 europe: other asia pacific (tel) 31 20 547 2111 countries: (tel) (65) 6375 8100 japan: (fax) (65) 6755 0042 (tel) (81) 426 56 7832 email: tm_ap@agilent.com (fax) (81) 426 56 7840 revised: 09/14/06 ? agilent technologies, inc. 2007 printed in usa, october 30th 2007 5989-7328en related agilent literature pub.no. agilent n4915a-005 serial bus switch 5989-7532en application in sata receiver test application note agilent j-bert n4903a 5989-2899en high-performance serial bert with complete jitter tolerance testing data sheet bert family brochure 5988-9514en brochure agilent parbert 81250 5968-9188e parallel bit error ratio tester product overview agilent pulse pattern and 5980-0489e data generators brochure agilent 81133a and 81134a 5988-5549en 3.35 ghz pulse pattern generators data sheet agilent n5990a test automation 5989-5483en software platform data sheet for more information, please visit us at www.agilent.com/? nd/sata_rx_test product speci? cations and descriptions in this document are subject to change without any notice. for the latest version of this document, please visit our website at: www.agilent.com/? nd/sata_rx_test and go to the key library information area or insert the publication number (5989-7328en) into the search engine. www.agilent.com/find/emailupdates get the latest information on the products and applications you select. www.agilent.com/find/agilentdirect quickly choose and use your test equipment solutions with con- fidence. www.agilent.com/find/open agilent open simplifies the process of connecting and program- ming test systems to help engineers design, validate and manu- facture electronic products. agilent offers open connectivity for a broad range of system-ready instruments, open industry soft- ware, pc-standard i/o and global support, which are combined to more easily integrate test system development.


▲Up To Search▲   

 
Price & Availability of N495A-005

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X